Bancs d’essai dynamique vanne et compteurs densimetres

Main features by zones

A ZONE – Demo part

    • Hydraulic valve [V100] – Pressure reduce function (PR)
      – Pressure sustain function (PS)
      – Flow control function (FC)
      – Combination of functions (PR-PS, PS-FC, PR-FC, PR-PS-FC)
      – Remote control of set point pilot by a linear actuator
    • Hydraulic valve [V200] – Piezometric control level
      – Floating control level
    • Hydraulic valve [V600]:
      – 2 way solenoid valve with pressure management software control
    • Degassing air valve [V700]
    • Counterweight butterfly valve with speed-check [V800]
    • Needle valve [V500] remote positioning control
    • Needle valve [V400] PID control system
      – Pressure reduce function (PR)
      – Pressure sustain function (PS)
      – Flow control function (FC)
      – Combination of functions (PR-PS, PS-FC, PR-FC, PR-PS-FC)
      – Remote control of set point by remote control software

B ZONE – Hydropass zone

    • Pressure test and flowmeter compare test on Hydropass products
    • Automatic control system

C ZONE – ISO test: MID & Kv

    • ISO condition zone test according to MID directive and EN 1267